Technical Diagnostics: Gloucester Road Engineering
Why is my door opening randomly?
This is often 'ghosting' caused by radar interference or sensor drift. In Gloucester Road, we see this frequently with older analog sensors. We upgrade these to digital units that filter out environmental noise.
Component Analysis
Drive Unit: The motor gearbox often suffers from stripped nylon gears. We replace the assembly to restore torque.
Safety Beams: We test the 'monitored' status of safety beams to ensure the door reverses immediately upon detecting an obstruction.
BS EN 16005 Compliance Matrix
Safety is mandatory. Our audits check specific parameters:
| Test Parameter | Limit | Action |
|---|---|---|
| Dynamic Impact | < 400N | Adjust motor torque |
| Static Entrapment | < 150N | Test safety reversal |
| Sensor Monitoring | Every Cycle | Verify controller feedback |
Engineer FAQ: Gloucester Road
Do you offer 24/7 callouts in Gloucester Road?
Yes, we have a rapid response team dedicated to the Gloucester Road area.
Do you repair Record operators?
Yes, we are independent specialists capable of repairing Dorma, Dorma, and most major brands using compatible parts.